The newest version of the ACTIA clone Multi-Diag Access J2534 Pass-Thru OBD2 device interface, equipped with V2016.01 software, is now available at obdii365.com. This updated I-2016 Multi-diag software from China conveniently eliminates the need for activation, streamlining the setup process for users.
Software Version: I-2016
Language Support: English, Spanish, German, French, Italian, Portuguese, Bulgarian, Croatian, Czech, Danish, Dutch, Finnish, Hebrew, Hungarian, Polish, Romanian, Russian, Serbian, Slovenian, Swedish, Turkish
Compatible OS: Windows XP
Important Installation Note: Ensure your network connection is disabled throughout the software installation process to prevent any interruptions.
Step-by-Step Guide to Installing V2016.1 Multi-diag Access J2534 Software
Step 1: Software Setup for Multi-diag J2534
Begin by inserting the software CD and copying the provided Serial Number (SN) key pad to your computer desktop for easy access. Then, initiate the setup process.
Click “Next” to proceed, and then accept the terms of the license agreement.
Continue by clicking “Next”.
The installation will prompt you to enter the VCI serial number. Open the key pad document you copied earlier, paste the SN 033918 into the field.
Click “Next” and select your preferred setup language.
Choose the setup type Profile ACTIA (Standard).
Click “Next”. The installer will now proceed with installing MSVisual C++, the main setup, and necessary drivers. This process will create a Multi-diag shortcut icon on your desktop.
Upon completion, select “Yes, I want to restart my computer now” and click “Finish” to complete the first step.
Step 2: Installing the Multi-diag J2534 Pass-thru USB Driver
Connect your Multi-diag access J2534 pass-thru device to your computer via USB. Select “Install the software automatically (Recommended)” when prompted.
Click “Next”. The system will search for and install the Pass Thru USB driver. Once completed, click “Finish”.
To verify successful connection, navigate to “My Computer” -> “Manage” -> “Device Manager” -> “I+ME ACTIA XS Device” -> “Pass Thru+xs USB Driver”. This confirms that a stable connection has been established.
Step 3: Communication Interface Update
Open the Multi-diag software from the shortcut on your desktop and select “Multi-diag”.
Choose your vehicle model year and module, for example, “VW” -> “PASSAT VI (2005-2011)” -> “Engine system” -> “VAG diagnostics”.
The system will initiate a communication interface update.
Acknowledge the warning message by clicking the tick icon.
If a message appears stating “The vehicle communication card cannot be reached, confirm to try again, Cancel to ignore,” click the tick icon to retry.
Ensure “Pass Thru+xs USB Driver” is checked. If the warning reappears, click the “No” icon.
If Multi-diag displays an “AWFInterpreter Security ERROR” warning, click the Tick button to proceed.
The system will attempt the communication interface update again. If you encounter an “Error while downloading the VCI” message, ensure the device is correctly connected to both your computer and the vehicle. Click the tick icon to retry.
Return to the software’s vehicle selection menu, click on the car icon, and turn on the vehicle ignition key.
Step 4: Pass-thru Driver Installation (Crucial for Vehicle Testing)
Important: Installing the Pass-thru driver is essential to enable vehicle testing. Select “Install from a list or specific location (Advanced)” and click “Next”.
Specify the driver save location as C:/ACTIA/Drivers VCI/PT1G.
Click “Next”. Once the USB passthru driver installation is complete, click “Finish”.
Verify the driver installation and the connection between the Multi-diag diagnostic scanner interface, your computer, and the vehicle by checking “Manager” -> “Device Manager” -> “PC–******” -> “ACTIA USB Devices” -> “USB PassThru Driver”.
The system should now detect the vehicle VIN and protocol. You are now ready to begin vehicle diagnostics and testing with your Latest I-2016 Multi-diag Access J2534 Pass-thru Obd2 Device.